5-Channel Precision Temperature Monitor
with Beta Compensation
14 ______________________________________________________________________________________
Table 7. Status 1 Register
BIT
NAME
POR
STATE
FUNCTION
7 (MSB)
Reserved
0
6
Local ALERT
0
Local Channel High-Alert Bit. This bit is set to logic 1 when the local
temperature exceeds the temperature threshold limit in the local ALERT high-
limit register.
5
Reserved
0
4
Reserved
0
3
Remote 4 ALERT
0
Channel 4 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the
channel 4 remote-diode temperature exceeds the temperature threshold limit
in the remote 4 ALERT high-limit register.
2
Remote 3 ALERT
0
Channel 3 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the
channel 3 remote-diode temperature exceeds the programmed temperature
threshold limit in the remote 3 ALERT high-limit register.
1
Remote 2 ALERT
0
Channel 2 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the
channel 2 remote-diode temperature exceeds the temperature threshold limit
in the remote 2 ALERT high-limit register.
0
Remote 1 ALERT
0
Channel 1 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the
channel 1 remote-diode temperature exceeds the temperature threshold limit
in the remote 1 ALERT high-limit register.
BIT
NAME
POR
STATE
FUNCTION
7 (MSB)
Reserved
0
6
Reserved
0
5
Reserved
0
4
Reserved
0
3
Remote 4 OVERT
0
Channel 4 Remote-Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 4 remote-diode temperature exceeds the temperature
threshold limit in the remote 4 OVERT high-limit register.
2
Reserved
0
1
Reserved
0
0
Remote 1 OVERT
0
Channel 1 Remote-Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 1 remote-diode temperature exceeds the temperature
threshold limit in the remote 1 OVERT high-limit register.
Table 8. Status 2 Register